350ºF Gas-Fired Jumbo Walk-in Oven for Processing Composite Structures

No.996 is a gas-fired, 350ºF (177ºC) jumbo walk-in oven, currently used for batch processing large composite structures.  Workspace dimensions measure 10’ W x 32’ D x 8’ H.  1,200,000 BTU/HR are installed in a modulating natural gas burner to heat the unit, while 49,000 CFM total from two (2) 20HP recirculating blowers provide combination airflow to the workloads.

996

This Grieve jumbo walk-in batch oven features 4” insulated walls throughout, removable top-mounted heat chamber (shown removed in photo), the oven body split into four 

(4) sections for shipment with mating angle iron frames for easy reassembly in the field, plus aluminized steel interior and exterior.

All safety equipment required by IRI, FM and National Fire Protection Association Standard 86 for gas-heated equipment are onboard No. 996, including an 8000 CFM powered forced exhauster for quick purge and cool down, motorized dampers on the intake and exhaust for accelerated cooling, as well as a 10” diameter circular chart recording and programming temperature controller.

For more information, please contact:

THE GRIEVE CORPORATION
500 Hart Road
Round Lake, IL 60073-2898
Phone: (847) 546-8225
Fax: (847) 546-9210
Web: www.grievecorp.com
Email: sales@grievecorp.com
Attention: Frank Calabrese, VP

Continue reading

350ºF (177ºC) Gas-fired Jumbo Walk-in Oven

996 GrieveNo. 996 is a gas-fired, 350ºF (177ºC) jumbo walk-in oven, currently used for batch processing large composite structures.  Workspace dimensions measure 10’ W x 32’ D x 8’ H.  1,200,000 BTU/HR are installed in a modulating natural gas burner to heat the unit, while 49,000 CFM total from two (2) 20HP recirculating blowers provide combination airflow to the workloads.

This Grieve jumbo walk-in batch oven features 4” insulated walls throughout, removable top-mounted heat chamber (shown removed in photo), the oven body split into four (4) sections for shipment with mating angle iron frames for easy reassembly in the field, plus aluminized steel interior and exterior.

All safety equipment required by IRI, FM and National Fire Protection Association Standard 86 for gas-heated equipment are onboard No. 996, including an 8000 CFM powered forced exhauster for quick purge and cool down, motorized dampers on the intake and exhaust for accelerated cooling, as well as a 10” diameter circular chart recording and programming temperature controller.

For more information, please contact:

THE GRIEVE CORPORATION
500 Hart Road
Round Lake, IL  60073-2898
Phone:  (847) 546-8225
Fax:  (847) 546-9210
Web:  www.grievecorp.com
Email:  sales@grievecorp.com
Attention:  Frank Calabrese, VP

Continue reading